Adverse Pressure Gradient Wind Tunnel

 

The Adverse Pressure Gradient Wind Tunnel is an open-return low-speed wind tunnel. Briefly, it has a 7.5 m overall length and a 17:1 contraction ratio of the bell-mouth nozzle section. The diffuser is 2.3 m long with a continuous transition from the rectangular test section to the circular fan housing. The test section is 3 m long by 0.3 m wide. The ceiling of the wind tunnel consists of thirty-six individual Plexiglas sheets, which are used to adjust the test-section geometry for a specific adverse pressure gradient configuration. Free-stream turbulence intensities for zero pressure gradient and adverse pressure gradients are about 1 % and 1.5 %, respectively. The motor is capable of free-stream velocities ranging from 2.5 m/s to 25 m/s.

 

Schematic of UC Davis Adverse Pressure Gradient Wind Tunnel

 

 

Home | Facilities | Research | People | Publications | Links